The proof: Case Studies
The estimated investment cost in the comparison with current energy prices takes into account e.g., the increased insulation and cladding material costs and inflation, and therefore an estimated increase has been added to the cost of insulation investment.
# 1. Refinery | Oil storage tank roof
Storage temperature: 60°C / 140°F
The situation: The roof of an aged storage tank containing oil at 60 °C was heavily corroded.
The solution: The roof was replaced with a basic 30 mm insulation solution equivalent to the VDI Energy Class G, applied with a long-lasting and effective corrosion protection system.
SAVINGS | SAVINGS BEFORE (energy price € 0,025) | SAVINGS NOW (energy price € 0,10) |
---|---|---|
Energy savings | Saved 7.500 MWh of energy / year | Saved 7.500 MWh of energy / year |
Financial savings |
Saved € 185.000 per year (Investment € 400.000) |
Saved € 750.000 per year (Investment € 560.000) |
Payback time | Less than 2,5 years | Less than 8 months |
CO2 emissions | CO2 emissions reduction potential 1.500 t/year | CO2 emissions reduction potential 1.500 t/year |
Financial savings on reduced CO2 emissions | € 0 (enough free allowances) |
CO2 price of € 80/t € 120.000 additional savings per year |
Total financial savings potential |
€ 185.000 per year € 1.45 million in 10 years |
€ 870.000 per year € 8.1 million in 10 years |
# 2. Chemical Plant
Process temperature: from 75°C/ 167°F to 150°C/ 302°F
The situation: 650 m of piping with missing or damaged insulation, 300 uninsulated pairs of flanges, 160 uninsulated valves, 3 uninsulated tanks
The solution: Full implementation of the remediation recommendations presented in the TIPCHECK Report, offering great energy and financial savings.
SAVINGS | SAVINGS BEFORE (energy price € 0,02) | SAVINGS NOW (energy price € 0,10) |
---|---|---|
Energy savings | Saved 11.000 MWh of energy / year | Saved 11.000 MWh of energy / year |
Financial savings |
Saved € 220.000 per year (Investment € 200.000) |
Saved € 1.1 million per year (Investment € 280.000) |
Payback time | Less than 1 year | Less than 4 months |
CO2 emissions | CO2 emissions reduction potential 2.240 t/year | CO2 emissions reduction potential 2.240 t/year |
Financial savings on reduced CO2 emissions | € 0 (enough free allowances) |
CO2 price of € 80/t € 179.200 additional savings per year |
Total financial savings potential |
€ 220.000 per year € 2 million in 10 years |
€ 1.25 million per year € 12.2 million in 10 years |
# 3. Refinery
Process temperature: 260°C/ 500°F
The situation: 1 uninsulated valve 12’
The solution: Insulating the valve to benefit from energy and money savings and to emit less CO2.
SAVINGS | SAVINGS BEFORE (energy price € 0,028) | SAVINGS NOW (energy price € 0,10) |
---|---|---|
Energy savings | Saved 114 MWh of energy / year | Saved 114 MWh of energy / year |
Financial savings |
Saved € 3.200 per year (Investment € 3.000) |
Saved € 11.400 per year (Investment € 4.200) |
Payback time | Less than 1 year | Less than 5 months |
CO2 emissions |
CO2 emissions reduction potential 51 t/year |
CO2 emissions reduction potential 51 t/year |
Financial savings on reduced CO2 emissions | € 0 (enough free allowances) |
CO2 price of € 80/t € 4.080 additional savings per year |
Total financial savings potential |
€ 3.200 per year € 28.800 in 10 years |
€ 15.480 per year € 150.600 in 10 years |